Loading... Please wait...
  • 760 Ventilator
  • Puritan Bennett 760

Refurbished PB 760

Call
SKU: TD 760-REB
Availability:
(866) 490-1609
Condition:
Refurbished
Weight:
155.00 LBS

760 Manufacturer Specifications

View "760" Items  
MODEL: 760
ALERTS (CONFIGURATION):  
Gas supply malfunction (ALERTS): Yes
Power loss (ALERTS): Yes
Vent inoperative (EQUIPMENT ALARMS): Yes
Low battery (EQUIPMENT ALARMS): Yes
SELF-TEST: Electronics and pneumatics
Additional (Alarms, high/low): Disconnect, occlusion
Battery (POWER NEEDED): Yes
DIMENSIONS (HXWXD) CM,(IN) (ALERTS): 37.8 x 51.5 x 37 (14.9 x 20.3 x 14.6) without cart 1
WEIGHT, kg (lb) (DISPLAY): 30 (66.2) ventilator, 18 (39.7) cart 125.5 x 51.5 x 37 cm (49.4 x 20.3 x 14.6 in) withcart.
Factory/on-site (Service): Yes/yes
TRAINING (SYSTEM CONFIGURATION): Yes
3rd-party service (Service): Yes
Parts availability (ALERTS): To customers, others
Delivery time, aro (SHOCK-WAVE GENERATOR): 45 days
Year first sold (PURCHASE INFORMATION): 1998
Usa/worldwide:  
Fiscal year (SHOCK-WAVE GENERATOR): July to June
REGULATORS:  
Tidal volume, ml (CONTROLS): 40-2,000
Insp flow, l/min (REGULATORS): 3
Insp press, cm h2o (REGULATORS): 29342
Respiratory rate, breaths/min (REGULATORS): 25569
Insp time, sec (CONTROLS): 0.2-8
Exp time, sec (REGULATORS): >0.2
I:e ratio (REGULATORS): 1:99 to 4:1
Insp hold/plateau (REGULATORS): 0-2 sec
Fio2, % (CONTROLS): 21-100
Manual breath (REGULATORS): Yes
Peep/cpap, cm h2o (REGULATORS): 0-35
Nebulizer (REGULATORS): Ultrasonic
Trigger system (REGULATORS): Flow
Pressure slope/ramp adjustment (REGULATORS): Yes
POWER NEEDED, VAC (ENERGY): 100-240
Current, amps (REGULATORS): 2.9 (115 V)
POWER CONSUMPTION, W (OTHER AVAILABLE ROTORS): 290
MONITORED PARAMETERS:  
Pip (MONITORED PARAMETERS): Yes
Map (MONITORED PARAMETERS): Yes
Peep (MONITORED PARAMETERS): Yes
Tidal (Volume): Yes
Minute (Volume): Yes
Spontaneous minute (Volume): Yes
Fio2 (PATIENT ALARMS): Yes
Inspiration time (MONITORED PARAMETERS): Yes
Expiration time (MONITORED PARAMETERS): Yes
I:e (CONTROLS): Yes
Additional (Alarms, high/low): E-sense
DISPLAYS (STAINING POSTS): LCD
PNEUMATIC POWER (Volume):  
Compressed gases (EQUIPMENT ALARMS): O2
Pressure ranges (EQUIPMENT ALARMS): 40-90 psi
INTERFACING:  
Output ports (INTERFACING): RS232 (2)
Remote alrm/display (INTERFACING): Yes
DISPLAY: Optional
Hard copy (Report generation): Yes
Archival disk (Report generation): Yes
Network (Report generation): Yes
DATA DISPLAYED (REGULATORS): Numbers, optional graphics
MODES OF OPERATION:  
Volume breaths (Assist/control): Yes
Pressure breaths (Assist/control): Yes
Volume breaths (Assist/control): Yes
Pressure breaths (Assist/control): Yes
Pressure support (Simv): Yes
Apnea-backup vent (Spontaneous/cpap): Yes
Additional (Alarms, high/low): Occlusion cycling, disconnect
OTHER SPECIFICATIONS (AIR SUPPLY): Exhalation sensitivity; rise time percentage; integral O2 sensor; 2-5 hr (optional 7 hr) battery backup. Meets requirements of CISPR 11; CSA; IEC 60601-1, 60601-2, and 60601-2-12; and UL.
FDA CLEARANCE (Interference compensation): Yes
CE MARK (MDD) (Interference compensation): Yes
WHERE MARKETED: Worldwide

Image is for illustration purpose only.

 


Warranty:
 
Covered by our 6 month no hassle warranty.

This product hasn't received any reviews yet. Be the first to review this product!

Write your own product review

90 Days

Sign up for our newsletter

All prices are in USD. Sitemap

View Cart Go To Checkout